MOBIL OIL CORP -- AUTOMATIC TRANSMISSION FLUID 210 -- 9150-00B130099
===================== Product Identification ===================== Product ID:AUTOMATIC TRANSMISSION FLUID 210 MSDS Date:12/30/1992 FSC:9150 NIIN:00B130099 === Responsible Party === Company Name:MOBIL OIL CORP Address:3225 GALLOWS ROAD City:FAIRFAX State:VA ZIP:22037-0001 Country:US Info Phone Num:800-424-9300 Emergency Phone Num:609-737-4411 CAGE:3U728 === Contractor Identification === Company Name:MOBIL OIL CORP, NORTH AMERICAS MARKETING AND REFINING Address:3225 GALLOWS ROAD Box:City:FAIRFAX State:VA ZIP:22037 Country:US Phone:800-662-4525/ 856-224-4644 CAGE:3U728 ============= Composition/Information on Ingredients ============= Ingred Name:ZINC (SARA III) CAS:7440-66-6 RTECS #:ZG8600000 Fraction by Wt: .04% Other REC Limits:NONE SPECIFIED OSHA PEL:10 MG ZNO/M3 ACGIH TLV:10 MG ZNO/M3; 9192 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:ZINC DIALKYL DITHIOPHOSPHATE CAS:68457-79-4 Fraction by Wt: .61% Other REC Limits:NONE SPECIFIED Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-DEWAXED HEAVY PARAFFINIC CAS:64742-65-0 RTECS #:PY8038500 Fraction by Wt: 95.0% Other REC Limits:NONE SPECIFIED ACGIH TLV:5 MG/M3 (OIL MIST) Ingred Name:REFINED HEAVY PARAFFINIC DISTILLATES CAS:64741-88-4 Fraction by Wt: >95.0% Other REC Limits:NONE SPECIFIED OSHA PEL:5 MG/M3 (OIL MIST) ACGIH TLV:5 MG/M3 (OIL MIST) Ingred Name:REFINED HEAVY PARAFFINIC DISTILLATES CAS:64741-88-4 Fraction by Wt: >95.0% Other REC Limits:NONE SPECIFIED OSHA PEL:5 MG/M3 (OIL MIST) ACGIH TLV:5 MG/M3 (OIL MIST) Ingred Name:DISTILLATES, SOLVENT-REFINED LIGHT NAPHTHENIC CAS:64741-97-5 RTECS #:PY8041000 Fraction by Wt: >95.0% Other REC Limits:NONE SPECIFIED OSHA PEL:300 PPM ACGIH TLV:300 PPM Ingred Name:2-PROPENOIC ACID, 2-METHYL-, BUTYL ESTER, POLYMER WITH N- (3-DIMETHYLAMINO PROPYL)-2-METHYL-2-PROPENAMIDE CAS:50867-55-5 Fraction by Wt: <2.0% Other REC Limits:NONE SPECIFIED Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED LIGHT NAPHTHENIC CAS:64742-53-6 RTECS #:PY8036000 Fraction by Wt: 0.39% Other REC Limits:NONE SPECIFIED OSHA PEL:5 MG/M3 (OIL MIST) ACGIH TLV:5 MG/M3 (OIL MIST) ===================== Hazards Identification ===================== LD50 LC50 Mixture:TLV: 5.00 MG/M3 Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:IRRITATING TO EYES & SKIN. Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT CARCINOGENS. Effects of Overexposure:NONE. Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS OR WITH A PRE-EXISTING DISEASE INVOLVING THE SKIN MAY BE AT INCREASED RISK FROM EXPOSURE. ======================= First Aid Measures ======================= First Aid:EYES: FLUSH WITH RUNNING WATER FOR 15 MINUTES WHILE HOLDING EYELIDS OPEN. SKIN: WASH WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING. INGESTION: DO NOT INDUCE VOMITING. RINSE MOUTH & DRINK LARGE AMO UNTS OF WATER. GET MEDICAL ATTENTION. ===================== Fire Fighting Measures ===================== Flash Point Method:COC Flash Point:350F,177C Lower Limits:.6% Upper Limits:7.0% Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY CHEMICAL. Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED CONTAINERS WITH WATER SPRAY. Unusual Fire/Explosion Hazard:NONE ================== Accidental Release Measures ================== Spill Release Procedures:ABSORB ON FIRE RETARDANT TREATED SAWDUST, DIATOMACEOUS EARTH, ETC. SHOVEL UP AND DISPOSE OF AT AN APPROPRIATE WASTE DISPOSAL FACILITY. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. KEEP CONTAINERS CLOSED WHEN MATERIAL IS NOT IN USE. KEEP AWAY FROM IGNITION SOURCES. AVOID PROLONGED OR REPEATED CONTACT. Other Precautions:NONE ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NONE Ventilation:LOCAL AND MECHANICAL(GENERAL) EXHAUST TO PROVIDE ADEQUATE VENTILATION. Protective Gloves:NONE Eye Protection:SAFETY GLASSES - CHEMICAL SPLASH GOGGLES Other Protective Equipment:NONE Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE EATING, DRINKING OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. Supplemental Safety and Health AVOID PROLONGED OR REPEATED EXPOSURE. DO NOT GET ON SKIN OR IN EYES. DO NOT INGEST. READ PRECAUTIONS ON LABEL BEFORE USE. ================== Physical/Chemical Properties ================== HCC:V6 Boiling Pt:B.P. Text:>600F,>316C Melt/Freeze Pt:M.P/F.P Text:NA Vapor Pres:<.1 Vapor Density:0.868 Solubility in Water:NEGLIGIBLE Appearance and Odor:RED LIQUID, MILD ODOR Corrosion Rate:N/KNOWN ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZING AGENTS Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND OTHER SOURCES OF IGNITION Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSAL OF WASTE AND HAZARDOUS MATERIAL SHALL COMPLY WITH LOCAL, STATE AND FEDERAL ENVIRONMENTAL PROTECTION AGENCY REGULATIONS. SEND WASTE MATERIAL TO AN APPROVED RECYCLING FACILITY IF FEASIBLE. CITY , STATE AND FEDERAL REGULATIONS MUST BEFOLLOWED. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.