GASTECH INC -- NITROGEN -- 6665-00N080828
=====================  Product Identification  =====================

Product ID:NITROGEN
MSDS Date:03/27/1995
FSC:6665
NIIN:00N080828
=== Responsible Party ===
Company Name:GASTECH INC
Address:8407 CENTRAL AVE
City:NEWARK
State:CA
ZIP:94560-3431
Country:US
Info Phone Num:510-794-6200
Emergency Phone Num:800-535-5053
CAGE:DO808
=== Contractor Identification ===
Company Name:GAS TECH INC. JOHNSON INSTRUMENT DIV
Address:8445 CENTRAL AVE
Box:City:NEWARK
State:CA
ZIP:94560-3431
Country:US
Phone:510-794-6200
CAGE:51906
Company Name:GASTECH INC
Address:8407 CENTRAL AVE
Box:City:NEWARK
State:CA
ZIP:94560-3431
Country:US
Phone:510-794-6200
CAGE:DO808

=============  Composition/Information on Ingredients  =============

Ingred Name:NITROGEN
CAS:7727-37-9
RTECS #:QW9700000
Fraction by Wt: 100%
OSHA PEL:N/K 
ACGIH TLV:ASPHYXIANT

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: ASPHYXIATION,
    DIZZINESS, HEADACHE, PARESTHESIA, UNCONSCIOUSNESS, DEATH. CHRONIC:
    ACUTE EFFECTS MAY BECOME CHRONIC. TARGET ORGAN: RESPIRATORY SYSTEM.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE IDENTIFIED.

=======================  First Aid Measures  =======================

First Aid:INGEST: CALL MD IMMEDIATELY . EYES: IMMEDIATELY FLUSH
    W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM
    MD . SKIN: FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD . INHAL: 
    PROVIDE FRESH AIR OR OXYGEN AND CONSULTMD.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE METHODS APPROPRIATE TO SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:COMPRESSED GAS CYLINDERS MAY EXPLODE IN
    HEAT OF FIRE. WITHDRAW IMMEDIATELY IN CASE OF RISING SOUND FROM
    VENTING SAFETY DEVICE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AND VENTILATE AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE SAFE HANDLING PRACTICES FOR THE
    HANDLING OF COMPRESSED GAS CYLINDERS. DO NOT PUNCTURE.
Other Precautions:STORE IN A COOL, DRY AREA. USE SAFE STORAGE PRACTICES
    FOR THE STORAGE OF COMPRESSED GAS CYLINDERS. EXPOSURE TO
    TEMPERATURES ABOVE 150F MAY OPERATE EXCESS-PRESSURE VALVE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NECESSARY IF ADEQUATE VENTILATION IS
    PROVIDED. USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
    CONCERN .
Ventilation:RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

Vapor Density:0.97
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS, ODORLESS GAS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE IDENTIFIED.
Stability Condition to Avoid:NONE IDENTIFIED.
Hazardous Decomposition Products:NONE IDENTIFIED.

====================  Disposal Considerations  ====================

Waste Disposal Methods:EMPTY CONTAINERS MAY BE DISCARDED AS METAL
    REFUSE, OBSERVING FEDERAL, STATE AND LOCAL REGULATIONS. DO NOT
    INCINERATE.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.