CASTROL NORTH AMERICAN -- MOTOR OIL -- 9150-00N072314
=====================  Product Identification  =====================

Product ID:MOTOR OIL
MSDS Date:11/02/1993
FSC:9150
NIIN:00N072314
=== Responsible Party ===
Company Name:CASTROL NORTH AMERICAN
Address:16715 VON KARMAN AVE SUITE 230
City:IRVINE
State:CA
ZIP:92714-4952
Country:US
Info Phone Num:714-660-9414
Emergency Phone Num:714-660-9414
CAGE:2R128
=== Contractor Identification ===
Company Name:CASTROL INDUSTRIAL NORTH AMERICA INC SPECIALTY PRODUCTS
    DIV
Address:1001 WEST 31ST STREET
Box:City:DOWNERS GROVE
State:IL
ZIP:60515-1280
Country:US
Phone:800-621-2661/ FAX: 630-241-4140
CAGE:2R128

=============  Composition/Information on Ingredients  =============

Ingred Name:KEROSENE (PETROLEUM), HYDROTREATED; (LIGHT HYDROTREATED
    DISTILLATE) LD50 (ORAL RAT): > 8 ML/KG
CAS:64742-47-8
RTECS #:OA5504000
Fraction by Wt: 20-25%
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CONT WILL CAUSE SKIN & EYE
    IRRIT. ELEVATED TEMPS/MECH ACTION MAY FORM VAPS, MISTS/FUMES WHICH
    MAY BE IRRITATING TO EYES, NOSE, THROAT & UPPER RESP TRACT.
    CHRONIC: MAY CAUSE DERM & DEFAT. INTENS IVE EXPOS MAY CAUSE CNS
    DEPRESS WHICH MAY LEAD TO LOSS OF COORD & IMPAIRED JUDGMENT. PRLNG
    EXPOS MAY RSLT IN UNCON.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH IMMED W/COPIOUS AMOUNTS OF WATER FOR AT LEAST 15
    MINUTES. CONSULT MD IF IRRIT DEVELOPS. SKIN: REMOVE CONTAMINATED
    CLOTHING IMMED & WASH BEFORE REUSE. WASH AFFECTED AREAS IMMED
    W/SOAP & WAT ER. CONSULT MD IF IRRIT DEVELOPS. INGEST: SEEK IMMED
    MEDICAL ATTENTION. DO NOT INDUCE VOMITING BECAUSE OF RISK OF ASPIR.
    INHAL: MOVE TO FRESH AIR. IF BREATHING IS DIFFICULT, GIVE OXYGEN.
    CONSULT MD.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:194F,90C
Extinguishing Media:CARBON DIOXIDE, DRY POWDER, SAND.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
    EQUIPMENT . WATER MAY CAUSE FROTHING, ONLY USE TO COOL FIRE-EXPOSED
    SURFACES.
Unusual Fire/Explosion Hazard:HAZARDOUS COMBUSTION PRODUCTS: OXIDES OF
    CARBON. PROTECT PERSONNEL, AND/OR SUPPRESS EXPLOSIVE VAPORS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:PREVENT ENTRY INTO WATER SOURCES. SOAK UP WITH
    A SUITABLE ABSORBENT SUCH AS SAND OR DIATOMACEOUS EARTH.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID REPEATED AND PROLONGED SKIN
    CONTACT. PREVENT EYE CONTACT. AVOID BREATHING MISTS OR VAPORS.
Other Precautions:STORE IN A COOL, DRY WELL-VENTILATED AREA, AWAY FROM
    HEAT AND IGNITION SOURCES. KEEP DRUMS AND CONTAINERS CLOSED WHEN
    NOT IN USE. COMBUSTIBLE LIQUID. KEEP AWAY FROM HEAT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED UNDER NORMAL USE. USE NIOSH
    APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:GEN VENT & LOC EXHST REC. THIS IS A SOLV BASED PROD & AS
    SUCH PROPER VENT IS REQUIRED. BUILD UP OF FUMES/MISTS (SUP DAT)
Protective Gloves:IMPERVIOUS PVC RECOMMENDED.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:MAINTAIN HIGH STANDARD OF PERSONAL HYGIENE.
Supplemental Safety and Health
VENT: IN WORKING ATM MUST BE PREVENTED. ELEC & MECH EQUIP SHOULD BE
    SPARK-PROOF.

==================  Physical/Chemical Properties  ==================

Spec Gravity:0.865
Solubility in Water:INSOLUBLE
Appearance and Odor:LIQUID BLUE OIL, WITH PETROLEUM ODOR
Percent Volatiles by Volume:25

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
MAY REACT WITH STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FUMES, SMOKE, CARBON MONOXIDE AND
    CARBON DIOXIDE ARE PRODUCED ON COMBUSTION.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN APPROVED INCINERATOR OR USE
    LICENSED WASTE DISPOSAL FACILITY. DISPOSE OF IN ACCORDANCE W/LOCAL,
    STATE & FEDERAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.