MATHESON GAS PRODUCTS INC -- CARBON DIOXIDE -- 6830-00-245-0199
=====================  Product Identification  =====================

Product ID:CARBON DIOXIDE
MSDS Date:08/31/1997
FSC:6830
NIIN:00-245-0199
=== Responsible Party ===
Company Name:MATHESON GAS PRODUCTS INC
Address:530 WATSON STREET
City:WHITBY
Country:ON
Info Phone Num:973-257-1100
Emergency Phone Num:800-424-9300(CHEMTREC)/973-257-1100
CAGE:MATHE
=== Contractor Identification ===
Company Name:MATHESON CO DIV OF G D SEARLE MEDICAL PRODUCTS
Address:30 SEAVIEW DRIVE
Box:City:SCAUCUS
State:NJ
ZIP:07096
Country:US
Phone:201-867-4100
CAGE:96355
Company Name:MATHESON GAS PRODUCTS
Address:30 SEAVIEW DRIVE
Box:85
City:SECAUCUS
State:NJ
ZIP:07096
Country:US
Phone:201-867-4100
CAGE:MATHE
Company Name:MATHESON GAS PRODUCTS INC
Address:530 WATSON STREET E
Box:City:WHITBY,ONT, CANADA
State:ON
Country:CN
Phone:905-668-3397
CAGE:50696

=============  Composition/Information on Ingredients  =============

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5000 PPM
ACGIH TLV:5000PPM/30000STEL;96

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MAJOR HEALTH HAZ:DIFFICULTY
    BREATH.SHORT TERM-INHAL:RINGING IN EARS,NAU,RIREG
    HEARTBEAT,HEAD,DROWS,DIZZ,TINGLING SENS,VISUAL
    DISTRUBANCES,SUFFOCATION,CONVUL,COMA.SKIN:BLISTERS,FROSTBITE.EYE:IR
    RIT,BLUR  VISION.INGEST:FROSTBITE.LONG TERM-NO INFOR ON SIGNIFICANT
    ADVERSE EFFECTS.
Explanation of Carcinogenicity:PER MSDS:CARCINOGENICITY(US
    ONLY):NTP/IARC/OSHA:NO.
Effects of Overexposure:DIFFICULTY BREATHING.
Medical Cond Aggravated by Exposure:HEART OR CARDIOVASCULAR DISORDERS,
    RESPIRATORY DISORDERS.

=======================  First Aid Measures  =======================

First Aid:INHAL:WHEN SAF TO ENTER REMOVE FROM EXPO.USE BAG VALVE
    MASK/SIMILAR DEVICE TO PERFORM ART RESP(RESCUE BREATH)IF
    NEEDED.KEEP WARM/@REST.GET MED ATTN IMMED.SKIN:WASH IF
    NEEDED.FROSTBITE/FREEZ/CRYOGENIC  BURNS OCCUR WARM AREA IN WARM
    H2O.NOT AVAI GENTLY WRAP PARTS IN BLANKETS.ALLOW CIRCULATION TO
    RETURN NATURALLY.GET MED ATTN IMMED.EYE:UNLIKELY EMERG TREAT WILL
    BE REQUIRED.WASH W/LG AMTS OF H2O(SUPPL)

=====================  Fire Fighting Measures  =====================

Flash Point:NON-FLAMMABLE
Autoignition Temp:Autoignition Temp Text:NA
Lower Limits:NON-FLAMM
Upper Limits:NON-FLAMM
Extinguishing Media:USE REGULAR FOAM OR FLOOD W/FINE WATER SPRAY.
Fire Fighting Procedures:MOVE CNTNR FROM FIRE AREA W/O RISK.COOL CNTNR
    W/H2O SPRAY TIL WELL AFT FIRE IS OUT.STAY AWAY FROM TANKS
    ENDS.TK/RAIL CAR/TK TRUCK EVACUATION RADIUS:800M(SUPPLE)
Unusual Fire/Explosion Hazard:NEGL FIRE HAZ.CNTNR MAY RUPTURE/EXPLO IF
    EXPO TO HEAT.AVOID INHAL OF MATL/COMBUST BY-PROD.STAY UPWIND/KEEP
    OUT OF LOW AREAS.CONSIDER DOWNWIND EVACUATION IF LEAK

==================  Accidental Release Measures  ==================

Spill Release Procedures:DONT TOUCH SPILLED MATL.STOP LEAK IF POSSIBLE
    W/O PERSONAL RISK.KEEP UNNECESSARY PEOPLE AWAY,ISOLATE HAZ AREA &
    DENY ENTRY.VENTILATE CLOSED SPACES BEF ENTERING.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE/HNDL IAW ALL CURRENT
    REGS/STDS.KEEP SEPARATED FROM INCOMPATIBLE SUBST.SUBJ TO STORAGE
    REGS:OSHA 29CFR1910.101.
Other Precautions:MEASUREMENT METHOD:GAS COLLECTION BAG;GAS
    CHROMATOGRAPHY W/THERMAL CONDUCTIVITY DETECTOR;NIOSH III#S249.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:RESP/MAX USE CONC FRM NIOSH &/OR
    OSHA:10000PPM-ANY SUPP-AIR RESP;ANY SCBA W/FULL FCPC.ESCAPE-ANY
    APPRO ESCAPE-TYP SCBA.UNK CONC/IMMED DANGEROUS TO LIFE/HEALTH-ANY
    SUPP-AIR RESP W/FULL FCPC OPERATED IN  DEMAND/OTH +PRESS MODE W/SEP
    ESCP(SUPP)
Ventilation:BASED ON AVAI INFO ADDN VENTILATION IS NOT REQUIRED.ENSURE
    COMPLIANCE W/APPLICABLE EXPOSURE LIMITS.
Protective Gloves:NOT REQUIRED BUT RECOMMENDED.
Eye Protection:NOT REQUIRED BUT RECOMMENDED.
Other Protective Equipment:FOR GAS:PROTECTIVE CLOTHING NOT REQUIRED.FOR
    LIQ:WEAR APPROP PROTECTIVE COLD INSULATING CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
1STAID:NORMAL SALINE TIL NO CHEM EVIDENCE REMAINS(@LEAST 15-20MINS).GET
    MED ATTN IMMED.INGEST:UNLIKELY EMERG TREAT WILL BE REQUIRE.GET MED
    ATTN IF NEEDED.NOTE TO DR:FOR INHAL CONSIDER OXY. FIREFIGHT:(
    1/2MI).APPLY H2O FRM PROT LOCAT/SAF DIST.DONT GET H2O DIRECTLY ON
    MATL.RED VAP W/H2OSPRAY. RESP:SUPP;ANY SCBA W/FCPC.

==================  Physical/Chemical Properties  ==================

HCC:G3
Boiling Pt:B.P. Text:N/AVAI
Melt/Freeze Pt:M.P/F.P Text:-71F,-57C
Decomp Temp:Decomp Text:>3092F,>170
Vapor Pres:43700 @21C
Vapor Density:1.5
Spec Gravity:1.522 @21C
pH:ACID
Viscosity:NP
Evaporation Rate & Reference:NA
Solubility in Water:SOLUBLE
Appearance and Odor:COLORLESS ODORLESS GAS W/SLIGHT ACIDIC TASTE;
    (ACIDIC IN SOLUTION).
Percent Volatiles by Volume:NA
Corrosion Rate:NP

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
COMBUSTIBLE MATLS,OXIDZING MATLS,METALS SALTS,REDUCING AGENTS,METAL
    CARBIDE,METALS,BASES.
Stability Condition to Avoid:PROTECT FROM PHYSICIAL DMG/HEAT.CNTNR MAY
    RUPTURE/EXPLO IF EXPO TO HEAT.AVOID CONTACT W/WATER OR MOISTURE.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IAW ALL APPLICABLE REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.