AMERIGAS PROPANE I.P. -- PROPANE -- 6830-00N080056
===================== Product Identification =====================
Product ID:PROPANE
MSDS Date:03/01/1995
FSC:6830
NIIN:00N080056
=== Responsible Party ===
Company Name:AMERIGAS PROPANE I.P.
Box:965
City:VALLEY FORGE
State:PA
ZIP:19482
Country:US
Info Phone Num:610-337-1000
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:JO536
=== Contractor Identification ===
Company Name:AMERIGAS INC INDUSTRIAL GASES DIV
Address:LEIGHTON BLDG
Box:965
City:VALLEY FORGE
State:PA
ZIP:19481
Country:US
Phone:215-337-7000
CAGE:2W147
Company Name:AMERIGAS PROPANE I.P.
Box:965
City:VALLEY FORGE
State:PA
ZIP:19482
Country:US
Phone:610-337-1000
CAGE:JO536
============= Composition/Information on Ingredients =============
Ingred Name:ETHANE
CAS:74-84-0
RTECS #:KH3800000
Fraction by Wt: 0.5.0%
OSHA PEL:N/K
ACGIH TLV:ASPHYXIANT
Ingred Name:PROPANE. % (WT):87.5-100
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: <100%
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT
Ingred Name:PROPENE; (PROPYLENE) (SARA 313)
CAS:115-07-1
RTECS #:UC6740000
Fraction by Wt: 05.0%
OSHA PEL:N/K
ACGIH TLV:ASPHIXIANT
Ingred Name:BUTANE; (BUTANES)
CAS:106-97-8
RTECS #:EJ4200000
Fraction by Wt: 0-2.5%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:ETHANETHIOL; (ETHYL MERCAPTAN)
CAS:75-08-1
RTECS #:KI9625000
Fraction by Wt: 0-50%PPM
OSHA PEL:C 10 PPM
ACGIH TLV:0.5 PPM
Ingred Name:SUPDAT:APPLYING WATER TO CNTNR WHICH HAS BEEN EXPOSED TO
HEAT/FLAME FOR MORE THAN SHORT TIME. FOR UNCONTROLLABLE(ING 7)
RTECS #:9999999ZZ
Ingred Name:ING 6:FIRES & WHEN FLAME IS IMPINGING ON CONTAINER,
WITHDRAW ALL PERSONNEL & EVACUATE VICINITY IMMEDIATELY.
RTECS #:9999999ZZ
Ingred Name:EFTS OF OVEREXP:EYE CONT: LIQ MAY CAUSE FREEZE BURN SIMILAR
TO FROSTBITE. SKIN CONT: LIQ MAY CAUSE FREEZE BURN (ING 9)
RTECS #:9999999ZZ
Ingred Name:ING 8:SIMILAR TO FROSTBITE. OTHER: PROPANE & SOME OF MINOR
COMPONENTS HAVE BEEN RPTD TO BE CARD SENSITIZERS (ING 10)
RTECS #:9999999ZZ
Ingred Name:ING 9:IN EXPERIMENTS.
RTECS #:9999999ZZ
Ingred Name:SPILL PROC:SWITCHES ON & OFF. EVAC AREA. IF POSS, REMOVE
LEAKING CNTNRS TO SAFE AREA. STOP FLOW OF GAS/ALLOW VAP(ING 12)
RTECS #:9999999ZZ
Ingred Name:ING 11:TO DISPERSE IN SAFE AREA. WATER SPRAY CAN BE USED TO
HELP DILUTE VAP CONC IN AIR. POSSIBILITY EXISTS THAT(ING 13)
RTECS #:9999999ZZ
Ingred Name:ING 12:LEAKS WILL NOT BE DETECTABLE BY SMELL. USE OF
PROPANE GAS DETECTORS I/A/W MFR'S INSTRUCTIONS IS REC. (ING 14)
RTECS #:9999999ZZ
Ingred Name:ING 13:ENVIR EFTS:AVOID UNCONTROLLED RELEASES OF MATL. LIQ
RELEASE WIL HAVE POSS EFT ON PLANT & ANIMAL LIFE. (ING 15)
RTECS #:9999999ZZ
Ingred Name:ING 14:LG LIQ RELEASE WILL QUICKLY VAPORIZE TO PRDCE A LRG,
VAP CLOUD. VAP CLOUD IS BOTH FIRE & ASPHYXIATION HAZARD.
RTECS #:9999999ZZ
Ingred Name:OTHER PREC:W/VAP SPACE. SOME CYLS HAVE DIRECTIONAL ARROWS
INDICATING UPRIGHT POSITION. DO NOT DROP/ABUSE CYLS. (ING 17)
RTECS #:9999999ZZ
Ingred Name:ING 16:DO NOT ALLOW CYLS TO RUN EMPTY. KEEP CNTNR VALVE
CLSD & PLUGGED WHEN NOT IN USE: IF CYL RUNS EMPTY, CLOSE(ING 18)
RTECS #:9999999ZZ
Ingred Name:ING 17:SHUTOFF VALVE IMMED. INSTALL PROT CAPS WHEN CYLS ARE
NOT CONNECTED FOR USE. EMPTY CNTNRS RETAIN SOME (ING 19)
RTECS #:9999999ZZ
Ingred Name:ING 18:RESIDUE, SO THEY SHOULD BE TREATED AS IF THEY WERE
FULL.
RTECS #:9999999ZZ
Ingred Name:RESP PROT:TO ACHIEVE FULL CONFORMANCE W/ACCEPTABLE
CRITERIA. USE NIOSH APPRVD RESP PROT (SUPPLIED AIR/SCBA (ING 21)
RTECS #:9999999ZZ
Ingred Name:ING 20:AS APPROP) RESPS SHOULD BE SELECTED BASED ON FORM &
CONC OF CONTAMINANT IN AIR & I/A/W OSHA (29CFR1910.131).
RTECS #:9999999ZZ
Ingred Name:EYE PROT:& FULL LENGTH FACESHIELD
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: ASPHYXIANT IN HIGH CONCS
DUE TO DILUTION OF AVAIL OXYG. AT EXCESS VAP CONCS, THIS PROD HAS
ANESTH, ASPHYXIATING PROPERTIES & MAY CAUSE SLEEPINESS. AT LEVELS
>100,000 PPM (I.E. 10%), PROP ANE IS MILDLY IRRITATING TO RESP
TRACT & MAY RSLT IN DIZZ, HEADACHE, DROW, NAUS, SHORTNESS OF
BREATH, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: MUSCULAR INCOORDINATION, EXCESS
SALIVATION, DISORIENTATION, VOMIT, & EXCITATION. IN EXTREME CASES,
CONVLS, UNCON & DEATH MAY OCCUR AS RSLT OF ASPHYX. PERSON WITH
CHRONIC RESP DISEASE SHOULD AVOID EXPOS. INGEST: LIQ MAY CAUSE
FREEZE BURN SIMILAR TO FROSTBITE. INGEST NOT EXPECTED TO OCCUR IN
NORMAL USE.(ING 8)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE INTO FRESH AIR. PROVIDE OXYG IF BRTHG IS DFCLT.
IF VICTIM IS UNCON, GET PROMPT MED ATTN. SKIN:IF FREEZE BURN
OCCURS, REMOVE CONTAMD CLTHES, SHOES & JEWELRY; IMMERSE BURNED AREA
IN WARM (N OT HOT) WATER. KEEP IMMERSED. GET PROMPT ATTN. EYE CONT:
FLUSH IMMED W/WATER FOR @ LST 15 MINS. OBTAIN IMMED MED ATTN.
INGEST: GET IMMEDIATE MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:-156F,-104C
Lower Limits:2.2%
Upper Limits:9.6%
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:NIOSH APPRVD SCBA & FULL PROT EQUIP . ELIM
SOURCES OF IGNIT. EVAC AREA. NOTIFY FIRE DEPARTMENT. ALLOW ONLY
TRAINED, PROPERLY PROTECTED PERS IN (SUPDAT)
Unusual Fire/Explosion Hazard:UNCONTROLLED VAPORS SPREAD RAPIDLY, ARE
HEAVIER THAN AIR AND ARE EXTREMELY FLAMMABLE.
================== Accidental Release Measures ==================
Spill Release Procedures:PROD IS EXTREMELY FLAM. VAP IS HVR/AIR & MAY
COLLECT @ LOWER LEVELS. FLAM CONCS MAY BE PRESENT BELOW NOSE LEVEL.
IF THERE IS LEAK BUT NO FIRE, DO NOT IGNITE ESCAPED GAS. ELIM ALL
IGNIT SOURCES. DO NOT SMOKE, DO NOT USE NEARBY PHONE/TURN ELEC
(ING 11)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN AUTHORIZED LOCATION (OUTSIDE,
DETACHED STOR IS PREF W/ADEQ VENT). ISOLATED FROM HEAT & IGNIT
SOURCES. ISOLATE FROM COMBUST MATERIALS.
Other Precautions:PROVIDE SEPARATE STOR LOCATIONS FOR OTHER
COMPRESSED/FLAM GASES. INSPECT CYLS FREQUENTLY FOR LEAKS, DENTS,
GAUGES & CORR W/EMPHASIS ON BOTTOM OF CYL. KEEP CYLS IN UPRIGHT
POSITION @ ALL TIMES SO THAT PRESS RELIEF VALVES COMMUNICATE (ING
16)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF CONCS ARE HIGH ENOUGH TO WARRANT SUPPLIED
AIR/SCBA, ATM MAY BE FLAMM. APPROP PREC MUST BE TAKEN REGARDING
FLAMMABILITY. FOR SITUATIONS WHERE FLAMMABILITY HAS BEEN SAFELY
ADDRESSED & WHERE CTL MEASU RES ARE NOT FEASIBLE/SUFFICIENT(ING 20)
Ventilation:USE LOCAL & DILUTION VENTILATION TO MAINTAIN EXPOSURES
BELOW ACCEPTABLE CRITERIA.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 22)
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . AVOID
SKIN CONT W/LIQ BECAUSE OF POSSIBILITY OF FREEZE BURN.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:AREA. SHUT-OFF SOURCE OF GAS, IF POSS. ALLOW FIRE TO
BURN ITSELF OUT AFTER GAS FLOW IS SHUT OFF. IF GAS FLOW CANNOT BE
SHUT OFF, DO NOT EXTING FIRE. ALLOW FIRE TO BURN ITSELF OUT USING
HIGH VOL WATER SUPPLY TO COOL HEAT-EXPOSED PRESS CNTNR FROM SIDE,
NEVER HEAD ENDS. USE EXTREME CAUTION WHEN (ING 6)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:-44F,-42C
Vapor Pres:196 PSIG
Vapor Density:1.50
Spec Gravity:0.504 (H*2O=1)
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:SLIGHT, 0.1 TO 1.0%
Appearance and Odor:COLORLESS, ODORLESS IN NATURAL FORM.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:KEEP AWAY FROM HIGH HEAT, SPARKS, OPEN
FLAME, STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION MAY YIELD CARBON
MONOXIDE, A TOXIC GAS.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF GAS I/A/W APPLIC FEDERAL, STATE &
LOCAL LAWS & REGS. VENT VAPOR IN SAFE LOCATION & ENSURE THAT GAS
DISSIPATES BELOW LOWER FLAMMABLE LIMIT. CONTROLLED BURNING IS
PREFERRED.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.